GFCI-AFCI COMPACT Tamper Resistant Angled Power Receptacles

GFCI-AFCI COMPACT Tamper Resistant Angled Power Receptacles
GFCI-AFCI COMPACT Slim Tamper Resistant Angled Power Receptacle

PRODUCT FEATURE SUMMARY

  • Features & Benefits:● Adequate room for wire connections
    ● Easy to close cover
    ● GFCI-AFCI tamper resistant duplex receptacles designed to protection you from injury.
    ● GFCI auto monitor, power denial technology.
    ● Clear indication if unit can no longer provide protection will flash RED) and will not reset.
    ● Only 1-15/16" in height
    ● Mounting hardware included
  • Specifications:

    ● 1-15/16" High x 5-9/16" Wide x 3-7/16" Deep
    ● 15 or 20 Amp
    ● GFCI
    ● UL Listed

  • Material Specifications:All-metal not plastic fixture
    Finishes:
    ● Satin White
    ● Satin Nickel
    ● Satin Black
    ● Oil Rubbed Bronze
    ● Brushed Stainless Steel
Your Price: $126.99

Register, to see applicable discounted price $$$ in shopping cart!

Part Number:CPW-241*CPW-C-

Select here to read more detailed Information

Choose Options

Fixture Type

More Info?

COMPACT 1-15/16" High x 5-9/16" Wide x 3-7/16" Deep
Insertion Devices
GFCI
GFCI-AFCI
Circuit Amps
20A
15A
Finish Colors

More Info?

Notes:
The latest National Electrical Code requires both GFCI (Ground Fault Circuit Interruption) and AFCI (Arc fault Circuit Interruption) protection only in kitchens and laundry rooms. And within those rooms, the Dual Function AFCI/GFCI Receptacle provides what is called “feed-through” protection, which means it provides protection for all wiring and extensions attached to the load side of the GFCI-AFCI. As an added benefit, AFCI receptacles offer the convenience of localized TEST and RESET on the face of the device.

The all-metal fixture GFCI-AFCI COMPACT Angled Power Strip provides a small profile fixture that can be mounted under or on the side of a cabinet.

GFCI Angled Power Distribution Strip
When a GFCI-AFCI circuit is required for any of the angled power strip receptacles and the main circuit breaker panel can not be adapted for a GFCI-AFCI circuit breaker, this alternative allows for the mounting of a GFCI-AFCI receptacle that can be used to feed all the Angled Power Strips with Ground Fault Circuit Interruption and Arc Fault Circuit Interruption protection.

GFCI Tamper ResistantThe GFCI-AFCI Angled Power Receptacle can be used when one duplex outlet is required or mounted side-by-side when additional receptacles are needed.

The GFCI-AFCI Angled Power Receptacles can be used standalone of which contains two plug-in receptacle outlets including the test and reset if the GFCI-AFCI happens to trip.

The GFCI-AFCI Angled Power Receptacle is UL Listed and CSA Certified which meets building code requirements. Available in 15 or 20 Amp.